Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	29
Date	08/07/14
Start Time	15:55:34
Diameter Midpoint
 11.3	729110
 11.8	851918
 12.2	809461
 12.6	823027
 13.1	837838
 13.6	850972
 14.1	859119
 14.6	860298
 15.1	859539
 15.7	855626
 16.3	845712
 16.8	833917
 17.5	819082
 18.1	796231
 18.8	769223
 19.5	736559
 20.2	686301
 20.9	639704
 21.7	594203
 22.5	542668
 23.3	482594
 24.1	422776
 25.0	364173
 25.9	307582
 26.9	251727
 27.9	198335
 28.9	154935
 30.0	116249
 31.1	87818.6
 32.2	63689.5
 33.4	46261.1
 34.6	32565.2
 35.9	22966.9
 37.2	16623.3
 38.5	12243
 40.0	9888.69
 41.4	8115.73
 42.9	7090.5
 44.5	5813.19
 46.1	5030.02
 47.8	4475.71
 49.6	4240.76
 51.4	4231.19
 53.3	4047.82
 55.2	3347.54
 57.3	2882.24
 59.4	2424.5
 61.5	2242.99
 63.8	2146.49
 66.1	2054.09
 68.5	1795.28
 71.0	1939.72
 73.7	2257.39
 76.4	2125.22
 79.1	1966.2
 82.0	1866.83
 85.1	1555.69
 88.2	1125.73
 91.4	1052.81
 94.7	855.845
 98.2	798.546
101.8	907.386
105.5	921.938
109.4	878.154
113.4	834.459
117.6	667.212
121.9	477.098
126.3	405.994
131.0	331.202
135.8	311.06
140.7	294.124
145.9	249.256
151.2	186.936
156.8	160.916
162.5	129.761
168.5	89.863
174.7	89.1967
181.1	87.3026
187.7	60.8993
194.6	53.8589
201.7	59.9143
209.1	52.0366
216.7	18.5804
224.7	40.721
232.9	36.5178
241.4	32.1234
250.3	25.883
259.5	38.4008
269.0	31.5066
278.8	28.3606
289.0	21.3823
299.6	25.4226
310.6	20.5461
322.0	21.4947
333.8	12.7379
346.0	9.84218
358.7	16.3395
371.8	5.96346
385.4	3.26366
399.5	12.5357
414.2	13.6449
429.4	5.29207
445.1	11.4871
461.4	4.85326
478.3	4.95205
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.6908
High Voltage	9932.41
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	16.5193
Mean(nm)	17.707
Geo. Mean(nm)	16.9863
Mode(nm)	14.5902
Geo. Std. Dev.	1.3166
Total Concentration(#/cm)	1.82741e+007
Comment	